Figure  2-76.  Shutdown  Position  Of  Control  Panel  Switches  And  Valves
Figure   2-77.   Total   Dissolved   Solids   (TDS)   Meter

TM-10-4610-215-10 Water Purification Unit Reverse Osmosis 600 GPH Trailer Mounted Flatbed Cargo 5 Ton 4 Wheel Tandem Rowpu Model 600-1 Manual
Page Navigation
  95    96    97    98    99  100  101    102    103    104    105  
TM    10-4610-215-10 TM   08580A-10/1 Table  2-5.  Shutdown  Position  of  Valve  or  Switch Order 1 2 3 4 5 6 7 8 9 10 11 12 13 Valve  or  Switch CHEMICAL  FEED  PUMP  (valves  (fig.  2-60) CHEMICAL  FEED  CONTROL  knobs  (fig.  2–59 REGULATE   PRODUCT   FLOW   valve VENT   PRODUCT   WATER   valve CAUTION After opening the regulate product flow valve fully, wait 5 minutes before opening vent vessels valve. VENT   VESSELS   valve VENT   CARTRIDGE   FILTER   valve VENT   PULSE   DAMPENER   valve VENT   MULTIMEDIA   FILTER   valve R.O.   PUMP   switch BOOSTER   PUMP   switch CHEMICAL   FEED   PUMP   switch RAW  WATER  PUMPS  NO.  2  switch RAW  WATER  PUMPS  NO.  1  switch Position PRIME 10.0  (Model  600-1) 8.5   (Model   600-3) OPEN OPEN OPEN OPEN OPEN OPEN STOP STOP STOP STOP STOP 2-31. OPERATION OF AUXILIARY EQUIPMENT. Operating  noise  level  of  the  generator  set  can  cause  hearing  damage.  Ear protectors, as recommended by the medical or safety officer, must be worn when working near set. Generator  sets  must  not  be  operated  in  enclosed  areas  unless  exhaust discharge is properly vented to the outside. Be alert at all times during operation for odors and exposure symptoms. 2-82







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.