  129    130    131    132    133  134  135    136    137    138    139  
TM    10-4610-215-10 TM  08580A-10/1 Table   3-2.   Troubleshooting   (ROWPU)   (continued) MALFUNCTION TEST   OR   INSPECTION CORRECTIVE   ACTION NOTE If the timer still fails to operate but there is electrical power to the timer box, you can manually backwash the filter. Step 3. Manually backwash filter as follows: a. With a small screwdriver or similar tool, press against the raised button on the white cam to rotate the cam counterclockwise to the BW (backwash) position (fig. 2–72). NOTE The   backwash   pump   should   start.   Allow   to   backwash   for   5   minutes. b.  Rotate  white  cam  to  rinse  position. NOTE Allow  filter  to  rinse  for  5  minutes. c. Rotate white cam to the SR (service) position. Backwash is now complete. d.  Report  defective  timer  to  unit  maintenance  for  replacement. 14.   BACKWASH   PUMP   DOES   NOT   START   WHEN   START   BACKWASH   SWITCH   IS   SET   TO START   (SOLID-   STATE   TIMER   -   MODEL   600-3) Step 1. Check that INTERNAL INDICATOR knob is in SERVICE position (view 1, fig. 2–74). Press RESET button to ensure knob is in SERVICE position. NOTE If backwash pump still does not start, filter can be manually backwashes. Step 2. Manually backwash multimedia filter as follows: a.  Turn  INTERNAL  INDICATOR  knob  counterclockwise  to  BACKWASH  position. Backwash  should  start. NOTE Allow  filter  to  backwash  for  10  minutes. 3-13







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.