Figure  3-5.  R.O.  Vessel  (Exploded  View)
Figure   3-7.   Element   Replacement

TM-10-4610-215-10 Water Purification Unit Reverse Osmosis 600 GPH Trailer Mounted Flatbed Cargo 5 Ton 4 Wheel Tandem Rowpu Model 600-1 Manual
Page Navigation
  139    140    141    142    143  144  145    146    147    148    149  
TM 10-4610-215-10 TM 08580A-10/1 CAUTION After removing R.O. element from sealed plastic bag, take care to keep element clean. Failure to do so will bring dust and dirt into R.O. elements and cause early element failure. (3)  Remove  new  R.O.  element  (4)  from  sealed  plastic  bag. (4) Refer now to fig. 3-6, and install brine seal (1) in groove of R.O. element (2) making sure open end faces R.O. pump end of ROWPU. (5) Insert by hand the first R.O. element (2) into R.O. vessel (3) until brine seal (1) touches end of R.O.  vessel. LEGEND: 1.   Brine   Seal 2.   R.O.   Element 3.   R.O.   Vessel NOTE (MC)  Direction  of  flow  is  indicated  on  the  side  of  each  element. Figure   3-6.   Element   Replacement (6)  Refer  now  to  fig.  3-7.  Place  interconnector  (1)  on  product  water  tube  (2)  of  first  R.O. element  (3). NOTE Do not confuse interconnector with end connectors. End connectors have a lip on the outside. 3-23