CHANGING  CARTRIDGE  FILTER  TUBE  ELEMENTS
Figure   3-12.   Cartridge   Filter   End   Plate   (Nut   Tightening   Sequence)

TM-10-4610-215-10 Water Purification Unit Reverse Osmosis 600 GPH Trailer Mounted Flatbed Cargo 5 Ton 4 Wheel Tandem Rowpu Model 600-1 Manual
Page Navigation
  144    145    146    147    148  149  150    151    152    153    154  
TM  10-4610-215-10 TM 08580A-10/1 (12) Operate ROWPU in normal manner (para. 2-25) and inspect cartridge filter for leaks. If there are leaks, shut down ROWPU (para. 2-31) and tighten cover nuts or replace O-ring as applicable. d.   Removal   (Model   No.   600-3). (1) Shut down ROWPU in the normal manner (see para. 2-31). (2)  Open  VENT  CARTRIDGE  FILTER  valve  (fig.  2-56). (3) Open DRAIN NO. 1 CARTRIDGE FILTER valve fully (para. 2-12). (4) Loosen six eyenuts (1) and washers (2) from the cover brackets (3). (5)  Use  quick  disconnect  and  remove  tubing  from  vent  (6). (6) Lift cover (4), remove O-ring (5) and hose on vent (6). Check O-ring for cracks, breaks and hardening.  Replace  O-ring  if  bad. LEGEND: 1.   Eyenut 2.   Washer 3.    Bracket 4.   Filter   Cover 5.   O-ring 6.    Vent 7.   Compression   Plate 8.   Tube   Guides 9.   Filter   Tube 10.   Sump   Seat Figure  3-11.  Cartridge  Filter  Tube  (Model  No.  600-3) (7)  Remove  compression  plate  (7)  with  tube  guides  (8). 3 - 28