Figure   2-25.   Typical   Field   Installation
Figure   227.   Raw   Water   System

TM-10-4610-215-10 Water Purification Unit Reverse Osmosis 600 GPH Trailer Mounted Flatbed Cargo 5 Ton 4 Wheel Tandem Rowpu Model 600-1 Manual
Page Navigation
  52    53    54    55    56  57  58    59    60    61    62  
TM   10-4610-215-10 TM  08580A-10/1 n. Refer  to  TM  5-5430-225-12&P  for  setup,  operation  and  maintenance  of  the  3,000  gallon self-supporting  water  tank. (Inside    Pouch) 1.   Filler   Fitting 5. Tank  Collar 2.   Discharge   Fitting 6. Cover Float 3.   Automotive   Valve 7. Handle  Toggles 4.   Inflation   Valve 8. Cover 9.   Foot   Bellows 10. Left Handles 11. Repair Pouch 12. Repair Kit Figure  2-26.  Typical  Water  Tank  Installation o. Attach float to strainer with enough rope to allow strainer to go under water but not touch bottom. Avoid placing the strainer near sandy areas. Hook up raw water system (fig. 2-30). Use only enough hose to reach from the water source to the ROWPU. CAUTION Ensure all hose connections are tight and seals are in place. Raw water pumps will not prime if the raw water hoses draw air. To prevent damage to ROWPU due to leaves and dirt, DO NOT operate pumps without strainer. 2-39







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.