• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure   2-38.   Vent   Product   Water   Valve
Figure   2-42.   Element   Cleaning   Switch

TM-10-4610-215-10 Water Purification Unit Reverse Osmosis 600 GPH Trailer Mounted Flatbed Cargo 5 Ton 4 Wheel Tandem Rowpu Model 600-1 Manual
Page Navigation
  65    66    67    68    69  70  71    72    73    74    75  
TM    10-4610-215-10 TM   08580A-10/1 Figure  2-40.  Product  Flow  Valve e. Control Box Switches. (1) Check switches in the control box assemblies. If you find any switch in the START or RUN position, set it to STOP or OFF. Figure  2-41.  Control  Box  Switches NOTE The switches marked START are spring loaded. Upon release they return to the middle  (RUN)  position.  The  ones  marked  JOG,  RESET,  and  START BACKWASH return to the normal position when released. (2) An indicator lamp is associated with each switch except for the EMERGENCY STOP button. Check the setting of the EMERGENCY STOP button. Pull button until it remains out when released. This is the normal operating position. f. Element cleaning switch. Check that the ELEMENT CLEANING switch is in the OFF position. It should be off at all times except while cleaning R.O. elements (para. 2–29). 2-52