Figure  2-41.  Control  Box  Switches
SAFETY VALVES

TM-10-4610-215-10 Water Purification Unit Reverse Osmosis 600 GPH Trailer Mounted Flatbed Cargo 5 Ton 4 Wheel Tandem Rowpu Model 600-1 Manual
Page Navigation
  66    67    68    69    70  71  72    73    74    75    76  
TM   10-4610-215-10 TM  08580A-10/1 Figure   2-42.   Element   Cleaning   Switch 9. Chemical Feed Pump Valves. Ensure all valves are in PRIME position (fig. 2-10). h. Backwash  Timer.  (Model  No.  600–1  ).  Ensure  white  cam  is  in  SR  position  (para.  2-26b(1)). (Model No. 600-3) Press RESET button on subpanel to ensure pilot controller valve is in SERVICE position (para. 2-26b (2)). i. Take an umarked pail and an adjustable wrench to the source of water. Check suction hoses in raw water to make sure strainer is under water. With the pail, draw some raw water from the source. Take it to raw water pump No. 1. Figure  2-43.  Raw  Water  Pump  (Prime  and  Drain) j. Check drain valves (petcocks) on the pump. If open, close them. Remove priming plug with your wrench. Fill pump with raw water. Screw priming plug back into pump. Return adjustable wrench to tool case. 2-53