SAFETY VALVES
Figure   2-46.   High/Low   Pressure   Lamps

TM-10-4610-215-10 Water Purification Unit Reverse Osmosis 600 GPH Trailer Mounted Flatbed Cargo 5 Ton 4 Wheel Tandem Rowpu Model 600-1 Manual
Page Navigation
  68    69    70    71    72  73  74    75    76    77    78  
TM    10-4610-215-10 TM  08580A-10/1 elements  (see  para.  2–28).  Also  notify  unit  maintenance  to  troubleshoot  the  HIGH  PRESSURE  RELIEF  VALVE and the HIGH PRESSURE SWITCH: 2-25. OPERATING PROCEDURES. a. Apply The power to the ROWPU. blue  lamp,  R.O.  PUMP NOTE LOW  PRESSURE,  on  ROWPU  control  box assembly comes on as soon as power is applied to the ROWPU. b. Push EMERGENCY STOP button in if any of the following conditions exist: Operating personnel could be injured or the equipment could be damaged if operation of the ROWPU is allowed to continue. (1) Blue HIGH PRESSURE lamp associated with R.O. PUMP comes on but R.O. Pump does not automatically stop. (2) Blue LOW PRESSURE lamp associated with R.O. PUMP comes on but R.O. Pump does not automatically stop. (3)  Some  other  serious  trouble  (malfunction)  indicated  by  noise,  vibration,  large  water  leaks, etc. Figure   2-45.   Emergency   Stop   Button 2-55