TM 10-4610-229-24 3-48.  STARTER REPAIR (CONT) 11 Slide  a  1/2  in.  pipe  coupling  or  cylinder  of  suitable  size  over  end  of  shaft  so  end  of  coupling  or  cylinder  butts against edge of retainer. 12 Tap end of coupling or cylinder with a hammer, driving retainer towards armature and off snapring. 13 Remove snapring from shaft.  Remove retainer. 14 Remove the armature and clutch from housing. 15 Separate solenoid from lever housing by pulling apart. 16 Remove plug from lever housing.  Remove and discard gasket. 17 Remove snapring, seal, shaft, and snapring from lever housing. 3-112