CABLES AND CONNECTORS
Installation  of  contacts  in  wrong  connector  sockets

TM-10-4610-232-34 Water Purification Unit Reverse Osmosis 3 000 GPH Trailer Mounted Flatbed Cargo 22-1/2 Ton 8 Wheel Tandem Model No. WTA-060 Manual
Page Navigation
  84    85    86    87    88  89  90    91    92    93    94  
TM    10-4610-232-34 NOTE When  crimping,  be  sure  to  make  a  good  electrical  and  mechanical  connection between terminal and wire. (5) Install and crimp splice (4) on each end of new wire (3). (6) Install and crimp the new wire splices onto the stripped end of the wire being repaired. (7) Using electrical tape, wrap the two splices for approximately one inch on each side of each splice. NOTE Make sure the electrical tape overlaps insulation on both ends of repair area. (8)  Using  electrical  tape,  completely  wrap  the  entire  length  of  cable  from  which  the  external  insulation  was removed.  When  possible,  install  heat  shrink  tubing. b. Replace Connectors (Figure 2-8). NOTE This procedure applies to both straight and 90° connectors and is applicable regard- less of the number of wires in the cable. (1) Cut boot (1) off cable (2) and discard. Unscrew backshell (3) from connector (4). (2) Tag all wires with their corresponding contact number. NOTE Contact numbers are marked on the interior of the connector. Figure 2-8. Connectors 2-86  Change 1