TM 10-4610-232-34
2-44. WASTE RELIEF VALVE. This task covers:
a. Removal.
b. Testing.
c. Adjust.
d. Installation.
Tools, see TM 10-4610-232-12, Appx B,
Sec Ill, Ref Code (No.)
Tool Kit, General Mechanics (1)
Dead Weight Tester (9)
Materials/Parts:
Gaskets (TM 10-4610-232-24P)
Equipment Condition:
ROWPU shutdown.
a. Loosen two thumbscrews (1 ) connecting valve assembly (3) to hose and piping.
b. Open two clamps (2) and remove valve assembly (3) from hose (4) and piping.
c. Remove two gaskets (5).
TESTING.
a. Connect the waste relief valve to a dead weight tester with a source of hydraulic pressure.
b. Increase the pressure until the valve relieves and note that pressure. The pressure at which the valve relieves
must be between 29 and 31 psi.
c. If it is not within the above limits, adjust the valve.
Figure 2-51. Waste Relief Valve
2-171