24 VDC POWER SUPPLY
REASSEMBLY. - TM-10-4610-232-34_223

TM-10-4610-232-34 Water Purification Unit Reverse Osmosis 3 000 GPH Trailer Mounted Flatbed Cargo 22-1/2 Ton 8 Wheel Tandem Model No. WTA-060 Manual
Page Navigation
  198    199    200    201    202  203  204    205    206    207    208  
TM    10-4610-232-34 Figure   2-58.   Power   Supply NOTE Wires in EMP (30) are molded and cannot be removed from EMP. b. Tag and disconnect all wires (27) which go from terminal board (33) to EMP modules (29 and 30). Remove the wires at the EMP modules by removing screws (28). C. Remove EMP modules (29 and 30) by removing four screws (31). d. Remove screws (32) and remove terminal board (33). 2-185