ACCESSORY  TABLE - TM-10-4610-232-34_251
REPAIR - TM-10-4610-232-34_253

TM-10-4610-232-34 Water Purification Unit Reverse Osmosis 3 000 GPH Trailer Mounted Flatbed Cargo 22-1/2 Ton 8 Wheel Tandem Model No. WTA-060 Manual
Page Navigation
  228    229    230    231    232  233  234    235    236    237    238  
TM    10-4610-232-34 2-66.  ACCESS  PANELS  AND  SEALS  (Including  Container  Shell).  This  task  covers: a.  Repair. INITIAL  SETUP. Tools,  see  TM  10-4610-232-12,  Appx  B. Sec Ill, Ref Code (No.) Tool Kit, General Mechanics Automotive (1) Riviter, Blind, Hand (4) Materials/Parts: Caulking (Appx B, Sec II, Item 9) Insulation    (TM    10-4610-232-24P) Rivets    (TM    10-4610-232-24P) Equipment  Condition: High pressure pump assembly removed (para.  2-67). General Safety Instructions: WARNING Observe specific Warning in text. References: TM   43-0139 WARNING Access panels can not be welded. They contain insulation which will give off deadly fumes  when  burned. Figure  2-73.  Access  Panels 2-213