TM   10-4610-232-34 Figure 3-6. High Pressure Pump CAUTION Take care not to damage housing bore. Scars on the housing could cause premature wear on the bearings and oil seals. NOTE Tag parts so they will be reassembled into the same bore from which they were removed. g. Tag and remove connecting rods (7) and cross head assemblies (19). h. Remove oil seal (20) from bearing housing (13). i. Remove setscrews (21) and wrist pins (22) from cross heads (23). 3-16