Troubleshooting (ROWPU) (continued) - TM-10-4610-239-10_145
Troubleshooting (ROWPU) (continued) - TM-10-4610-239-10_147

TM-10-4610-239-10 Water Purification Unit Reverse Osmosis 600 GPH Trailer Mounted Flatbed Cargo 5 Ton 4 Wheel Tandem Model 0996109001 Manual
Page Navigation
  127    128    129    130    131  132  133    134    135    136    137  
TM 10-4610-239-10 TM 08580B-10/1 Table 3-2.  Troubleshooting (ROWPU) (continued) MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION b    Check TDS sample from each R.O. vessel using TDS meter without range extender (para.2- 32c(5)). c.   Use these findings to make a chart like the following: R.O. Vessel TDS (ppm) NOTE 1 (TOP) 600 The numbers on this chart are 2 900 examples only.  Yours may vary. 3 1100 4 (Bottom) 1400 d. Examine pattern of chart TDS should get -larger from top to bottom. (1) If any R.O vessel does not follow this pattern, there is something wrong inside; disassemble the faulty vessel and replace defective items (see para 3-4). (2) If R.O vessels all follow this pattern, proceed to Step 2. Step 2. Check product water flow from each R.O vessel: a. Use  same  method  as  in  Step  1  to  collect  water  sample,  but  this  time  measure  the  time  in minutes it takes to fill a3gallon bucket with product water from each vessel.  Divide 3 by the number of minutes. b. Make a chart like the following: R.O Vessel FLOW (gpm) 1 (Top) 4 2 3 3 2 4 (Bottom) 1 3-7