Figure 2-43.  Vent Product Water Valve
Figure 2-47.  Element Cleaning Switch

TM-10-4610-239-10 Water Purification Unit Reverse Osmosis 600 GPH Trailer Mounted Flatbed Cargo 5 Ton 4 Wheel Tandem Model 0996109001 Manual
Page Navigation
  71    72    73    74    75  76  77    78    79    80    81  
TM 10-4610-239-10 TM 08580B-10/1 Figure 2-45.  Product Flow Valve e. Control Box Switches. (1) Check switches in the control box assemblies.  If you find any switch in the START or RUN position, set it to STOP or OFF. Figure 2-46.  Control Box Switches NOTE The switches marked START are spring loaded.  Upon release they return to the middle (RUN) position.  The ones marked JOG, RESET, and START BACKWASH return to the normal position when released. (2) An indicator lamp is associated with each switch except for the EMERGENCY STOP button.  Check the setting of the EMERGENCY STOP button.  Pull button until it remains out when released.  This is the normal operating position. f. Element cleaning switch.  Check that the ELEMENT CLEANING switch is in the OFF position.  It should be off at all times except while cleaning R.O. elements (para. 2-29). 2-57