TM10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
2-30. CHEMICAL CANS AND FRAME MAINTENANCE - continued.
b. Cleaning.
(1) Wash all components with clean water and detergent.
(2) Inspect components in clean water and dry with wiping rag.
c. Inspection.
(1) Inspect all threaded components for damaged threads.
(2) Inspect for clogged or cracked suction tube (15).
(3) Inspect for clogged or damaged strainer (16).
(4) Inspect stem (6) for bends or cracks.
(5) Inspect can (18) for cracks, splits, and broken or missing lid (24).
(6) Inspect frame (8) for cracks, bent or broken framework, and corrosion.
d. Repair.
(1) Replace damaged or missing components.
(2) If frame is bent, or damaged, or no longer serviceable, send to Direct Support Maintenance.
c. Assembly
(1) Apply anti-seize tape to male threads of all fittings. Be sure to wrap tape in same direction as thread.
(2) Install dust plug (21), adapter (22), and socket coupling (23) on flitting (17).
(3) Position fitting (17) and attached parts inside can (18).
(4) Install gasket (19) and knurled nut (20) on fitting (17).
(5) Install strainer (16) on suction tube (15).
(6) Install suction tube (15) and attached parts inside can (18).
(7) Install gasket (14) and knurled nut (13) on suction tube (15).
(8) Install adapter (12), dust cap (11) plug coupling (10) on suction tube (15).
(9) Screw stem (6) onto float (7).
(10) Position float (7), stem (6) and fitting (5) inside can (18).
2-138