TM 10-4610-241-24
TO 40W4-13-42
2-24.
GATE VALVES AND FITTINGS REPAIR - continued .
e.
Assembly.
(1)
Push packing (6) into place on stem (7).
(2)
Install gland (5) and packing nut (4). Tighten nut finger tight, then use wrench and tighten an additional 1/4 turn.
(3)
Position hand wheel (3) on stem (7).
(4)
Install washer (2) and nut (1).
2-119