TM 10-4619-241-24
TO 40W4-13-42
2-24.1 OCEAN INTAKE STRUCTURE REPAIR (MODELS H-9518-1, H-9518-2, AND
H-9618-3) - continued.
e.
Assembly.
(6)
Replace all other parts if unserviceable.
(1)
(2)
(3)
(4)
(5)
NOTE
Use anti-seize tape on all male threaded fittings when assembling.
Install wellpoint tip (24) onto riser pipe (23) on the end with the holes. Make sure gasket (25) is
seated properly.
Install screen (22) over riser pipe (23).
Slide guard (2 1) onto wellpoint (17) and install the wellpoint cap (19) and gasket (20).
If necessary, install boot (18) onto wellpoint (17) and secure with hose clamp (16).
Install the nipple (15), bushing (14), elbow (13), and fitting (12) to the wellpoint cap (19) by turning
clockwise.
3-120.6 Change 1