Table 3-1. Direct Support Troubleshooting - continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
DISTRIBUTION PUMP ASSEMBLY- continued
a.
b.
c.
d.
If continuity is absent through heater assembly, replace heaters (Paragraph 3-61)
and reset heater assembly.
If continuity is absent through K5 (see above note). replace motor starter. Refer to
Paragraph 3-61.
If continuity is absent thru CB5 (CBS ON), replace CB5. Refer to Paragraph 3-53.
If continuity is absent through wires, tighten loose connections and/or replace
defective wire.
3-27