TM 10-4610-241-24
TO 40W4-13-42
3-13.
CENTRIFUGAL PUMP MOTOR ( RAW WATER PUMP) REPAIR - continued.
(6)
Remove four through-bolts (10).
(7)
Tap fan end plate (11) with soft-faced mallet to break bond with stator assembly (20) and remove fan
end plate.
(8)
Remove wavy washer (12) and flat washer (13) from shaft of rotor (19).
(9)
Remove two screws (14).
(10)
Tap pump end plate (15) with soft-faced mallet to break bond with stator assembly (20) and remove
pump end plate (15).
CAUTION
Stator wiring in stator assembly can be damaged by rotor or shaft if rotor
is not removed carefully.
(11)
Remove rotor (19) from stator assembly (20).
(12)
Using arbor press, pull bearings (16 and 17) from shaft of rotor (19).
(13)
Remove bearing retainer plate (18).
(14)
Remove shaft cover (21).
3-129