TM 10-4610-241-24
TO 40W413-42
343.1
HIGH PRESSURE PUMP (RO. PUMP) MOTOR REPAIR (MODELS H-9518-1, H-9518-2, AND
H-9518-3) - continued.
NOTE
Marking relative position of casing and brackets will facilitate installation. Be sure to
transcribe markings to replacement parts if defective parts are to be discarded or turned
in to Supply.
(3)
Scribe a line across junctions of stator (16) and brackets (12 and 17).
(4)
Remove four nuts ( 18).
(5)
Tap bracket (12) with soft-faced mallet to break bond with stator (16). Remove bracket (12).
WARNING
Rotor is heavy/difficult to handle. Use two personnel when removing rotor from stator
assembly.
CAUTION
Stator assembly wiring inside motor casing can be damaged by rotor or rotor shaft if
rotor is not removed carefully. Guide rotor carefully while removing it.
(6)
Remove rotor ( 15).
(7)
Tap bracket ( 17) with soft-faced mallet to break bond with stator (16). Remove bracket.
(8)
Remove slinger ( 19) from bracket (17).
3-244.2 Change 1