TM 10-4610-241-24
TO 40W4-13-42
3-54. WIRING HARNESS, W3 REPAIR - continued.
f.
Installation.
(1) Position wiring harness (4) injunction box (10) and connect wires (2) to terminal points, stamped on wires
with screws (1).
(2) Tug wires inside clamps (9) and close clamps with tiedown straps (3) Install additional tiedown straps as
required to secure harness to existing wiring.
(3) If removed, install clamps (9) with screws (8), flatwashers (7), lockwashers (6) and nuts (5).
3-315