TM 10-4610-244-13 TM 09476B-13/1 4-13.  SERVICE FOOT VALVE AND TUBING (Cont'd). b. SERVICE (1) Replace tube in accordance with Appendix G, Item 4. (2) Clean all components of foot valve (3). (3) Inspect all components of foot valve (3) for damage Replace entire foot valve if any component damaged c. INSTALLATION (1) Install ceramic poppet (9) in body (6). (2) Slide screen (8) over body (6) and install adapter (7) onto body (3) Push suction tube (4) onto adapter (7) of foot valve and screw tube nut (5) onto adapter (4) Push tube (18) onto injection valve (20), and screw tube nut (19) on. (5) Push tube (18) onto discharge valve (17), and screw tube nut (16) on (6) Push tube (15) onto R-valve (14), and screw tube nut (13) on. (7) Push tube (4) onto suction valve (11), and screw tube nut (10) on. 4-11