4-17. TM  3-4230-218-12&P f. Installation. (1) (2) (3) (4) (5) (6) (7) (8) Install  igniter  (5),  two  washers  (4),  and  two  screws  (3).  To connect   igniter   wires   to   control   panel   refer   to   page   4-35. Connect  white  wire  to  No.  7  terminal  and  the  green/yellow  wire to  No.  12  terminal  of  terminal  strip. Position  burner  (8)  on  heat  exchanger  (15). Install   eight   washers   (14),   eight   lockwashers   (13),   and   eight screws  (12). Connect  burner  choke  cable  (6)  to  burner  (8). Secure  burner  choke  cable  (6)  to  burner  (8)  with  bolt  (7). Connect  ignition  wire  (9)  to  spark  plug  (10). Connect   fuel   lines   (1   and   2). Burner,   Installation. 4-34