Table 3-1. Operator Troubleshooting - Continued - TM-3-4230-218-12P_86
Table 3-1. Operator Troubleshooting - Continued - TM-3-4230-218-12P_88

TM-3-4230-218-12P Decontaminating Apparatus: Power-Driven Portable Type A/E32U-8 NSN: 4230-01-163-8660 Manual
Page Navigation
  65    66    67    68    69  70  71    72    73    74    75  
TM 3-4230-218-12&P MALFUNCTION TEST OR INSPECTION CORRECTIVE  ACTION Step 4. Check  for  clogged  suction  hose  strainer. If suction hose strainer is clogged, clean strainer (refer to page 3-22)  . 8. WATER COMES OUT PRESSURE RELIEF VALVE. Step 1. Check that manual pressure relief valve (1) plunger is seated by pulling out plunger ring (2) and letting it snap back. If plunger is seated, proceed to step 2. Step 2. Check WATER PRESS REGULATOR valve setting. If pressure exceeds valve. If water pressure is 100 psi, readjust correct, proceed water  pressure to step 3. Step 3. Check for kinked branch or pressure hoses. regulator If hoses are kinked, straighten hoses. If hoses are not kinked, proceed to step 4. 3-9