Table 3-1. Operator Troubleshooting - Continued - TM-3-4230-218-12P_93
DECONTAMINATING  APPARATUS  -  Continued

TM-3-4230-218-12P Decontaminating Apparatus: Power-Driven Portable Type A/E32U-8 NSN: 4230-01-163-8660 Manual
Page Navigation
  72    73    74    75    76  77  78    79    80    81    82  
TM 3-4230-218-12&P 3-6. DECONTAMINATING  APPARATUS  -  Continued. (2) Adjustment. (a) (b) (c) (d) (e) (f) (g) (h) Release  four  fasteners  (2)  and  remove  panel  (1). Loosen water pump belt tensioner attaching bolts (6). Move tensioner (7) as far to left as possible. Move water pump belt tensioner (7) to the right until roller (8) just touches belts (5). Move tensioner (7) an additional 1/4 inch to the right and securely  tighten  bolts  (6).  Replace  panel. Start  engine  and  run  unit  for  approximately  30  minutes. Shut unit down and carefully reach in and touch fan hub (3).   (This hub is the drive pulley for the water pump.) If hub surface is warm to touch, belts (5) need to be tightened. Tighten  belts  as  follows: (1) Using any sharp pointed instrument available, scribe position of left end of tensioner (7) on fan housing (4). (2) Slightly loosen two attaching bolts (6), but do not remove. (3) Push tensioner (7) 3/16 to 1/4 inch further to the right and while holding in place, securely tighten — ataching  bolts  (6). (4) Repeat steps (e) and (f) to verify adjustment. Reinstall panel (1) and lock four fasteners (2). Drive  Belts,  Adjustment. 3-16