TM 3-4230-237-10
0016 00
OPERATOR'S PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - Continued
Table 1. Before Operation PMCS for M12A1 DED Decontaminating Apparatus - Continued.
11
12
Procedure
Not Fully
Item
Interval
Man
Item to be
Mission
No.
Hour
Checked/
Capable If:
Serviced
Pump Unit
(Cont)
FUEL
BEFORE
11
NOTE
INDICATOR
FUEL INDICATOR may not return
to zero when system is off. Visually
check fuel tank to confirm fuel
quantity.
Check that FUEL INDICATOR registers when
IGNITION switch is turned to the RUN position.
FUEL
FUEL INDICA TOR
Check that centrifugal pump support is not broken,
Centrifugal pump
Pump Unit
BEFORE
12
cracked, or dented.
supports broken or
Subassembly
missing.
0016 00-9