TM 3-4230-237-10
0018 00
OPERATOR'S PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
Table 1. After Operation PMCS for M12A1 DED Decontaminating Apparatus.
3
4
Item
Interval
Man
Item to be
Procedure
Not Fully
No.
Hour
Checked/
Mission
Serviced
Capable If:
a. Inspect pump unit surfaces for cracks, dents,
Pump Unit
AFTER
3
damage, and deformation.
(1) Clean the exterior of the pump unit with hot,
soapy water then rinse with clear water.
(2) Lubricate according to Lubrication Instructions
b. Inspect canvas cover to see that all buckles, snaps,
and straps are in good condition and not corroded or
damaged. If cover is unserviceable and needs to be
replaced, notify Unit Maintenance.
Make sure the camlock fasteners securely lock the
Cover Panels
AFTER
4
panels to the pump unit.
0018 00-3