j.
Make sure power panel 3 (120 Vac) cir-
cuit breaker 11 P13 is closed (ON) to
provide heat to electric motors and
brakes to combat moisture and corro-
sion.
k. Visually check electric winch motors,
Wiring is frayed or
motor controllers, and wiring for damage
damaged.
or malfunction. Report deficiencies to
shift leader or bargemaster for corrective
action-
I.
Check winch manual brakes to assure
Brake bank is
brake bank is properly fastened and not
excessively worn.
excessively worn.
*
m. Check and clean all electrical compo-
nents and wiring.