  79    80    81    82    83  84  85    86    87    88    89  
DECKMASTER 5.0     BRAKE Ausco No. 31025 Rated Torque:  3800 in-lbs 6.0     HYDRAULIC MOTOR TRW Ross No. MAB-10-0-Q2-A1 Displacement = 7.4 in3/Revolution Efficiency Torque = hT  = 0.87 Volumetric = hV = 0.92 Overall = hOA     = 0.80 Torque = 118 in-lbs/100 PSI (theoretical) Required Input Hydraulic Pressure 1883 1 = • 1.18 0.87 =  1834 PSI Required Input Flow                                 1 gal 1 = (281.1  Rev/min) (7.4 in3/Rev)       (           )            (        ) = 9.8 GPM 231 in3 0.92 7.0     HYDRAULIC PUMP Sundstrand No. 20-2065-HDC Rated Pressure = 3,000 PSI Efficiency:  Volumetric   h V = 0.95 Overall    h OA = 0.90 Flow = 14.6 GPM @ 1750 RPM Assume System Pressure Drop of 300 PSI Required Pump Output Pressure = 2134 PSI Required Electric Horsepower Max.      (2134) (14.6) = (1714) (0.90) = 20.2 Horsepower Normal         (2134) (9.8) = (1714) (0.90) = 13.6 Horsepower 2-4