TM 55-2090-201-14&P
3-38. FILTER ELEMENT (#) (Continued).
LOCATION
ITEM
ACTION
REMARKS
(2) Open the drain valve
(12) at the base of the
vessel.
Continue to
step f.
e. To drain water from the se-
cond or third stages (3 or
6):
(1) Close the two inter-
vessel shutoff valves
(13 and 14) on either
side of the second
stage (3) or the inter-
vessel shutoff valve
(13) for drainage of
the third stage (6).
(2) Open the drain valve (15
or 16) at the base of
the vessel.
NOTE
Wait until the water level has dropped slightly
before opening the cover.
When removing the cover, be careful not to damage
the float on the bottom of the air eliminator
valve.
f. Release and remove the cam
bar (17, 18 or 19) and re-
move the cover (20, 21 or
22) of the separator stage
being serviced.
Turn cover
over so that the float faces
upward and is not in contact
with surface.
3-240