3-42. PREFILTER
TM 55-2090-201-14&P
L O C A T I O N
I T E M
A C T I O N
R E M A R K S
Electrical shock or serious injury may result if
electrical power is not turned off before continu-
ing maintenance on the 1st stage (prefilter) sepa-
rator.
2. 1st stage a. Mini
(pre-
(1) Remove screws (1), cover
probe
filter)
(2) and gasket (3).
cover
separator
(2)
(2) Tag and disconnect ter-
electrical
minals (4).
connec-
tions
b. Solenoid Remove retaining cap (5),
valve
nameplate (6) and housing
housing (7).
c. Tees
and
Remove screws (8), cover (9)
and gasket (10).
pulling
elbow
covers
(11, 12
and 13)
d. Motor
(1) Unscrew collar (14) from
cable
connector (15).
(16)
(2) Tag and disconnect leads
(17) by removing connec-
tors (18).
(3) Tag and disconnect other
wiring and carefully re-
move each wire individu-
ally from electrical
connections.
e. Mini-
Unscrew.
probe
(19)
Use thin wall
socket NSN
5120-00-277-
1465 with
1/2 in. drive
ratchet.
3-276