Table 2-5. Shutdown Position of Valve or Switch
Order
1
2
3
4
5
6
7
8
9
10
11
12
13
Valve or Switch
CHEMICAL FEED PUMP (valves (fig. 2-60)
CHEMICAL FEED CONTROL knobs (fig. 259
REGULATE PRODUCT FLOW valve
VENT PRODUCT WATER valve
CAUTION
After opening the regulate product flow valve fully,
wait 5 minutes before opening vent vessels valve.
VENT VESSELS valve
VENT CARTRIDGE FILTER valve
VENT PULSE DAMPENER valve
VENT MULTIMEDIA FILTER valve
R.O. PUMP switch
BOOSTER PUMP switch
CHEMICAL FEED PUMP switch
RAW WATER PUMPS NO. 2 switch
RAW WATER PUMPS NO. 1 switch
Position
PRIME
10.0 (Model 600-1)
8.5 (Model 600-3)
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
STOP
STOP
STOP
STOP
STOP
2-31.
OPERATION OF AUXILIARY EQUIPMENT.
Operating noise level of the generator set can cause hearing damage. Ear
protectors, as recommended by the medical or safety officer, must be worn
when working near set.
Generator sets must not be operated in enclosed areas unless exhaust
discharge is properly vented to the outside. Be alert at all times during operation
for odors and exposure symptoms.