TM 10-4610-210-10
TM 08580A-10/1
d. Use one of the raw water pumps to force the water through the NBC cartridges. Install raw water
pump (fig. 2-83).
(1) Install 1 1/2 in. suction hose from raw water tank and swivel adapter on raw water pump.
(2) Attach female end of distribution (suction or discharge) hose to straight adapter on raw water
pump.
(3) Attach swivel adapter to gate valve and attach male end of distribution hose to swivel
adapter.
(4) Attach shoulder bushing and adapter to gate valve.
NOTE
The NBC cartridges should be positioned so that the cartridge marked FOR
USE WITH CHEMICALLY CONTAMINATED WATER ONLY is FIRST in the
series.
Position the cartridge marked FOR USE WITH RADIOACTIVE
CONTAMINATED WATER so that water is filtered through this cartridge LAST
as shown in figure 2-83.
e.
Assemble the NBC cartridge in series (fig. 2-83).
Be sure to follow the setup procedures in steps 1 through 4 below. Pay special
attention to the INPUT and OUTPUT labels on the top of the NBC cartridges
when connecting the 3/4 in. reinforced flexible tubing to the cartridges.
(1) Slide clamp over end of one section of 3/4 in. x 80 in. flexible tubing. Attach tubing to adapter
on gate valve and close clamp.
(2) Slide clamp over other end of tubing.
(3) Remove plug from INLET port on FOR USE WITH CHEMICALLY CONTAMINATED
WATER cartridge and insert adapter.
(4) Attach tubing to adapter on INLET port and close clamp.
(5) Cut one section of 3/4 in. x 80 in. flexible tubing to a maximum length of 24 in.
(6) Slide clamp over end of tubing.
(7) Remove plug from OUTLET port
WATER cartridge and insert adapter into cartridge.
on FOR USE WITH CHEMICALLY
(8) Attach tubing to adapter on OUTLET port and close clamp.
(9) Remove plug from INLET port on FOR USE WITH RADIOACTIVE
WATER cartridge and insert adapter into cartridge.
(10) Slide clamp over end of tubing.
CONTAMINATED
CONTAMINATED
2-101