TM 10-4610-215-24
TM 08580A-24/2
h. Power Cable Assembly Installation. (Figure 2-42)
(1)
(2)
(3)
box (13).
(4)
(5)
(6)
(7)
(8)
(9)
WARNING
ELECTRICAL HIGH VOLTAGE
Electricity can cause serious injury or death. Be certain that all
power is removed before performing maintenance on electrical
equipment.
Slip cable grip (12) over cable.
Insert tagged wires through hole in conduit box (13).
From inside of conduit box (13), slip cable grip nut (11) over wires and mount cable grip (12) to conduit
Slip tagged wire lugs (9) over three screws (10) in three pairs and remove tags.
Install flat washer (8), lockwasher (7), and nut (6) onto screw (10) of wire sets.
Wrap each set of wire lugs including screw and hardware with tape (5).
Tie wires into bundle with lacing cord (4).
Carefully insert wire bundle into conduit box (13).
Hold conduit box cover (2) and new gasket (3) in place.
(10) Install four screws (1) through conduit box cover (2), gasket (3), and conduit box (13).
RAW WATER PUMP ASSEMBLY
2-43.
a. General. The raw water pumps provide water from the source and supplies it tO the ROWPU for
purification. This paragraph describes removal of the power cable assembly from the motor, removal of the pump
from the frame, cleaning, inspection, and installation of the raw water pump assembly.
WARNING
ELECTRICAL HIGH VOLTAGE
Electricity can cause serious injury or death. Be certain that all
power is removed before performing maintenance on electrical
equipment.
b. Power Cable Assembly Removal, (Figure 2-44)
(1) Remove two screws (1) from conduit box (14) and conduit box cover (2).
(2) Remove conduit box cover (2) from conduit box (14).
(3) Pull wires out far enough to expose taped ends.
(4) Cut twine (3) that holds bundles together.
(5) Remove tape (4) from ends of each set of wires.
NOTE
Mark each set of wires for ease of reassembly later.
(6) Remove nut (5), lockwasher (6), and flat washer (7) from screw (9) on each set of wires.
(7) Remove all wire lugs (8) from screw (9) on each set of wires.
(8) Remove grounding screw (10) from inside of conduit box (14).
2-77