TM 10-4610-215-24
TM 08580A-24/2
(7) Replace damaged or unserviceable micro switches.
(8) Replace damaged cam.
(9) Replace all damaged, cracked, or bent switch insulators.
(10) Replace all damaged pipe fittings.
h. Printed Circuit Board and Timer Motor Reassembly. (Figure 323)
(1) Install new gasket (26) around edge of timer box (4).
(2) Install white controller cam (25) in timer box (4).
(3) Install bracket (23) in timer box (4) using two screws (24),
(4) install micro switch (22) and two insulators (21 ) on bracket (23) using two washers (20), two screws
(19), and two nuts (18).
(5) Install micro switch (17) on plate (13) using two washers (16), two screws (15), and two nuts (14),
(6) Install plate (13) in timer box (4) using two screws (12).
(7) Install ground lug (11 ) and four screws (10).
(8) Install timer motor (9) and two compression springs (8) in timer box (4) using two screws (7).
(9) Install printed circuit board (6) in timer box (4) using five screws (5).
(10) Connect electrical wires (1) to terminal strips (2) and (3) in accordance with schematic (figure 3-21),
(11) Check wiring and remove tags.
i. Sub-Plate Components Reassembly. (Figure 322)
(1) Check that printed circuit board (7) is installed.
(2) Install switch (6) on sub-plate (4) using nut (5).
(3) Install sub-plate (4) using four screws (3).
(4) Using an Allen wrench, install indicator knob (2) with setscrew (1).
(5) Close timer box cover.
3-102