TM 10-4610-229-10
2-4. ASSEMBLY AND PREPARATION FOR USE (CONT)
4
Attach 3/4 in. hose section to foot valve nipple. Attach other end of hose section to outlet of priming
pump.
5
Attach 3/4 in. hose section to strainer. Attach other end of hose to inlet of priming pump.
6
Install threaded rod through cam adapter, gasket, and pump flange. Place flatwasher, lockwasher, and
nut on each end of rod. Hand-tighten nuts, leaving equal lengths of rod at both ends. Repeat for other
three rods.
7
Tighten eight nuts alternately and equally.
2-71