TM 10-4610-232-12
Table 2-13. Operator Preventive Maintenance Checks and Services (PMCS)
(Continued)
Item
No.
Interval
Item to
Check/Service
Crewmember/Procedure
Not Fully Mission Capable If:
CAUTION
Ensure latching pins are secure;
otherwise, container could fall off
trailer in rough terrain.
10.
Before
Container Bolster
Check to make sure locks are
Damage that would prevent operation
Locks
properly set and safety chains
or wire ties missing.
are attached to trailer. Make sure
wire ties are secured to locking
devices.
WARNING
Make sure the circuit breaker for the
distribution pump and the winter kit
heat
lamp
is
turned
off
before
proceeding. Failure to do so could
result in electrocution.
11.
Before
Distribution
Inspect pump housing, motor,
Damage or missing parts that would
Pump and
and frame for cracks, damage, and
prevent operation.
Motor
missing hardware and parts.
12.
Before
Distribution
a. Check for cuts, loose connections,
Damaged or missing power cable that
Pump Power
and damaged connectors.
would prevent operation.
Cables and
b. If winter kit heater is installed,
Remote Cable
check it for damage, cable cuts, or
loose connections
13.
Before
Distribution
a. Inspect exterior casings for wear
Damage or missing parts that would
Suction and
and cuts.
prevent operation.
Discharge
b. Inspect gaskets at connections.
Hoses,
c. Inspect hoses for missing caps
Caps, Plugs and
and plugs.
Nozzles
d. Inspect nozzle/filter for damage.
Nozzle is inoperative or has missing
e. Inspect trigger, latches, and
parts.
springs for damage.
14.
Before
Storage Tanks
Perform PMCS IAW
Storage tanks inoperative.
TM 5-5430-225-12&P.
15.
Before
Ladders
Check for broken or cracked
Damage presents a hazard to
steps and loose hardware.
personnel or ladders missing.
Change 12 2-39