TM 10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
2-39.
THREADED PIPE MAINTENANCE- continued.
(2)
Hold up two-piece clamp (18) and remove two nuts (20), lockwashers (19) and screws (24)
(3)
Separate and remove two-piece clamp (18)
(4)
Remove ring filler (23) and insulation tape (17) from nipple (25)
c.
Remove adapter (7) and sensing tube (6) from threaded pipe (5)
d.
Disconnect pipe section as follows:
(1)
Locate nearest upstream and downstream pipe coupling points The coupling device may be a clamp or
threaded pipe union.
(2)
Disconnect pipe union (s) (14)
(3)
Remove two nuts (3), screws (1), coupling clamp halves (2), and gasket (4).
2-153