2-69. DIAPHRAGM PUMPS (CHEMICAL FEED PUMP) MAINTENANCE - continued.
d. Repair.
(1) Replace damaged components.
(2) Replace all o-rings and diaphragms.
e. Assembly.
(1) Install o-ring (31) valve ball (29) and ball stop (28) on valve body (30). Screw valve body into reagent head (3).
(2) Install o-ring (27), valve ball (25) and ball stop (24) in valve body (26). Install valve body (26) on valve body
(30).
(3) Install o-ring (23) on adapter (22) Install adapter in valve body (26).
(4) Install o-ring (34), valve ball (33), and ball stop (3 2) in valve body (35). Screw valve body into reagent head (3).
(5) Install o-ring (38), valve ball (37), and ball stop (36) in adapter (39). Install adapter in valve body (35).
2-250