TM 10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
3-14.
CENTRIFUGAL PUMP MOTOR (DISTRIBUTION PUMP) MAINTENANCE.
This task consists of:
a. Disassembly
b. Cleaning
c. Inspection
d. Repair
e. Assembly
f. Test
INITIAL SET-UP:
Tools Required
General Mechanics Tool Kit (Appendix B, Section III, Item 4)
Material/Parts Required
Rags, wiping (Appendix C, Section II, Item 23)
Gasket - 34GS1000
Gasket- 34GS1001
Equipment Condition
Reference
General Safety Instructions
WARNING
High voltages in this equipment can cause serious injury or death. Be
certain that all power is removed before performing maintenance.
Compressed air can blow dust into the eyes Wear eye protection Do not
exceed 30 psi (207kPa) air pressure
DISASSEMBLY
a.
Remove three screws (1) and fan cover (2)
b.
Remove screw and retainer (3), and external fan (4) from rotor shaft (10).
NOTE
Mark fan end plate, case, and pump end plate to assist in alinement during assembly
3-108