TM 10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
3-14. CENTRIFUGAL PUMP MOTOR (DISTRIBUTION PUMP) MAINTENANCE - continued.
f.
Position plate (13) Aline mark made during assembly with mark on stator assembly (9).
g.
Install washer (7) on short end of rotor shaft (10).
h.
While holding plate (13) alined on one end of stator assembly (9), position plate (6) on other end Aline mark
made on plate during disassembly with mark on stator assembly (9).
i.
Install four bolts (5).
j.
Install fan (4), and screw and retainer (3).
k.
Install fan cover (2) and three screws (1).
TEST
a.
Secure motor to test bench.
WARNING
Electrical high voltages can cause serious injury or death Some tests require
power to be connected. Always take proper measures to ensure personal safety.
b.
Connect motor wiring to test bench leads.
c.
Connect power and run motor with and without load.
d.
Check motor for excessive vibration and fast temperature rise.
e.
Disconnect motor from test bench leads
3-114