TM 10-4610-241-24
TO 40W4-13-42
2-67. HIGH PRESSURE PUMP REPAIR (MODELS WPES-10, WPES-20, and WPES-30) - continued.
(8)
Feed water drain hose (9) thru grommet (10) and position clamp (7) on hose (9).
(9)
Connect hose (9) to elbow (8) on pump assembly (24). Adjust and tighten clamp (7).
(10)
Install clamps (6 and 5) and secure with screws (4), lockwashers (3) and nuts (2).
(11)
Fill high pressure pump with oil in accordance with Service procedure of this Paragraph.
(12)
Operate ROWPU (TM 10-4610-241-10). Check for leaks and proper operation.
Change 1 2-263