TM 10-4610-241-24
TO 40W4-13-42
2-69. CONTROL VALVE AND PIPING REPLACE (MODELS WPES-10, WPES-20 and WPES-30) - continued.
b.
Installation.
NOTE
Be sure to wrap tape in same direction as pipe thread.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
Apply anti-seize tape to male pipe fittings.
If disassembled, assemble pipe section (51, 50, 49 and 48) in accordance with Paragraph 2-30.
Install pipe sections (51, 50, 49, 48) and adapter (47) on control valve (46).
Lubricate gaskets (41, 42, 43 and 45) and position on pipe sections (51, 50, 49, 48) and adapter (47).
Position control valve (46) with attached piping sections on unit and install U-bolt (40), two lockwashers
(39) and nuts (38).
Position gasket (41) over pipe joint and install two clamp halves (37), bolts (36). and nuts (35).
Position gasket (42) over pipe joint and install two clamp halves (34), bolts (33), and nuts (32).
Position gasket (43) over pipe joint and install two clamp halves (31), bolts (30). and nuts (29).
Position gasket (45) over pipe joint and install two clamp halves (25). bolts (24), and nuts (23).
Position gasket (44) over pipe joint and install two clamp halves (28), bolts (27), and nuts (26).
Connect metal tube (22) to pipe section (5 1) and tighten nut (2 1).
CAUTION
ROWPU will not operate properly and may be damaged if hoses are incorrectly installed.
If tags installed at removal are not legible or missing, connect tubes in accordance with
connection diagrams (Paragraph 2-68).
Connect tube ends (1, 2, 3, 4, 5, 6, 7, 8, 9 and 10) as marked or use diagram (Paragraph 2-68).
Operate ROWPU (TM 10-4610-241-10). Check for leaks and proper operation.
2-270 Change 1