Table 3-1. Direct Support Troubleshooting - continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
RAW WATER PUMP ASSEMBLY NO. 1-continued
a.
If continuity is absent through heater assembly, replace defective heaters (Paragraph 3-61)
and reset heater assembly.
b.
If continuity is absent through relay K3 (see above note), replace motor starter. Refer to
Paragraph 3-61.
c.
If continuity is absent through CB3 (CB3 ON), replace CB3. Refer to Paragraph 3-53.
d.
If continuity is absent through wires, tighten loose connections and/or replace defective
wire.
3-67