CENTRIFUGAL PUMP ( RAW WATER PUMP) REPAIR - continued.
(4)
Pry off rubber disk (11) and remove spring (12), sleeve (13) and carbon disk (14).
(5)
Remove bolt (15), lockwasher (16) and bracket (17).
NOTE
Marking position of adapter on motor will facilitate reassembly.
(6)
Scribe a line across motor (24) and adapter (20) junction and remove four screws (18) lockwashers (19)
and adapter from motor.
(7)
Remove slinger (23) from shaft of motor (24).
(8)
Remove rubber cup (22) and ceramic disk (21), from adapter (20).