TM 10-4610-241-24
TO 40W4-13-42
3-56.
WIRING HARNESS, W5 (GENERATOR) REPAIR - continued.
f.
Installation.
(1) Position gasket (10) on wiring harness (9) and position wiring harness in cutout on junction box (16).
(2) Install cap (7), screws (6), flatwashers (5), lockwashers (4) and nuts (3), securing wiring harness (9) to
junction box.
(3) Connect wires to components in unction box in accordance with information stamped on wires.
(4) If removed, install cable clamps (15) with screws (14), flatwashers (13), lockwashers (12) and nuts (11).
(5) Tug wiring harness (9) inside clamp (15) and close clamps (15) with tiedown straps.
(5) As required, secure wiring harness (9) to other harnesses with tiedown straps (8).
3-322