TM 10-4610-246-13
5.5
MAINTENANCE OF OUTLET PIPE ASSEMBLY
This task covers:
a.
Removal
c.
Installation
b.
Assembly
INITIAL SETUP
Parts/Materials
Equipment Conditions
Cleaner/Primer (Item 12, App. E)
Outlet pipe assembly removed (para 4.17).
Pipe Fittings (TM 10-4610-246-23P)
Adhesive (Item 9, App. E)
Ball Valve (TM 10-4610-246-23P)
NOTE
If one part is defective the entire assembly must be replaced.
a.
Repair.
Repair is accomplished by replacement of entire assembly.
NOTE
Apply cleaner/primer (Item 12, App. E) to pipe fittings before applying adhesive.
b.
Assembly.
(1)
Insert street elbow (1, Figure 5-1)
into ball valve (2).
(2)
Insert pipe (3) into street elbow (1).
(3)
Install tee (4) over pipe (3).
(4)
Temporarily install outlet pipe
assembly (refer to para 4.17d).
(5)
Scratch alignment marks on
assembled parts.
WARNING
Death or severe injury can occur from inhal- ing
fumes caused by inadequate ventilation while
using cleaner/primer and adhesive.
5-4
Figure 5-1. Outlet Pipe Assembly