TM 3-4230-218-12&P
b.
Burner Choke Control.
(1) Removal.
(a) Remove two bolts (8), two washers (6), and lever (2) from
control panel.
NOTE
It may be required to cut bend in lead to free cable from cable clamp.
(b) Loosen bolt (11) on cable clamp (3) and unscrew choke
cable (4) outer casing from lever (2).
(c) Loosen bolt (11) and disconnect lead (4) from burner
choke arm (9).
Pull lead from unit.
Burner
(2) Cleaning.
Choke Control, Removal.
WARNING
The cleaning solvent used emits strong vapors and is flammable.
To avoid
illness or fire, use in a well-ventilated area and away from open flames. DO
NOT breathe vapors for a prolonged time.
(a) Wash burner lever (2) and cable parts in cleaning solvent
(item 3, Appendix E) using a varnish brush (item 1,
Appendix E).
(b) Allow to dry.
4-53